<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-23 09-16-37
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 64 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.0 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 9919 10,2934
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
4,8 dBr 6,69 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 9:16, 23.09.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (63 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 10,2934 Acquired: 2025/09/23 9:15:33 Total samples: 9919 Equivalent time: 0:08:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000